Automatic temperature control valve
Pointer position at "0": all off
The pointer position is "*": antifreeze 8 ℃
Pointer position at "1": set 12°C
Pointer position at "2": set 16°C at night
Pointer position at "3": set 20°C during the day
Pointer position at "4": set 24°C
Pointer position at "5": set 28°C
The antifreeze position guarantees a minimum temperature of 8°C, which protects the system from damage and ensures that the system can still operate normally in severe cold weather.
➠
Description
Radiator automatic temperature control valve series. The Enetec automatic temperature control valve is composed of two parts: the temperature control valve and the automatic adjustment temperature bulb. The automatic temperature control valve is very similar to the traditional radiator valve, but the action of the closing element is different from the latter. The closing element of the thermostatic valve is automatically controlled according to the ambient temperature by a temperature-sensitive self-regulating bulb, which controls the closing element to maintain the set ambient temperature by adjusting the water flow of the radiator.